                              | How to solve the vortex flow meter problem |  8-04-2020 How to solve the vortex flow meter problems Vortex flow meters are mainly used to  measure the flow of medium fluids in industrial pipelines, such as gases,  liquids, vapors and other media .its characteristics are small pressure loss,  large measuring range, and high accuracy .it is almost independent of  parameters such as fluid density, pressure ,temperature, and viscosity when  measuring volume flow under working conditions. No moving mechanical parts, so  it has high reliability and low maintenance .instrument parameters can be  stable for a long time .this instrument uses a piezoelectric stress sensor with  high reliability and can work in the operation temperature range of -20¡æ~250¡æ¡£There are  imitation standard signals and digital pulse signal output, which is easy to be  used with digital systems such as computers. It is a relatively advance and  ideal flow meter.
 The main problems of vortex flow meter
 The main ones are:¢Ù. Inaccurate instructions for a long time ;¢Ú. There is no instruction for a long time ; ¢Û. The instructions are shaken in a wide range and cannot be read; ¢Ü.the instructions are not returned to zero;¢Ý. There are no instructions for small flows ;¢Þ. The change of the indicator cannot keep up when the fluid quality  changes;¢ß the K factor of the meter cannot be  determined, and there are no difference between the materials.
 Summarize the main causes of these problems  ,and mainly touched on the following aspects:
 
                              problems in the selection of  the vortex flow meters .some vortex sensors have a larger size in the selection  of the caliber or after the design selection due to changes in process  conditions. in practice, the smallest caliber should be selected to improve the  measurement accuracy. The reason for this is mainly the same Questions ¢Ù¢Ú¢Û are related. For example ,a vortex street pipeline is designed to  be used by several equipment. Due to the sometimes partial use of process  equipment, the current practical application flow is reduced. The original  application design is too large in size ,which is equivalent to improving the  measurable flow. At the lower limit ,the indication cannot be guaranteed when  the flow rate of the process pipeline is small, and it can be used when the  flow rage is large ,because it is sometimes too difficult to rebuild .changes in process conditions are only temporary .the  re-adjustment of the separable parameters indicates the degree of progress.  
 KFKC INSTRUMENT CO.,LTD specializes in the production of Electromagnetic flowmeter ,Vortex Flowmeter, Turbine Flowmeter for many years,complete specifications, various  forms, can meet your different needs in different occasions.                         
 |